In short
- A freestanding bath is a load before it is a finish: 200 litres of water is 200 kg, and a bather adds to a floor designed for less.
- Acrylic is light and quick to warm, solid surface can be sanded back, stone holds heat and needs sealing. Decide after the floor check.
- Specify declared empty weight, fill volume to the overflow, trap seal and the floor's imposed load. Those four numbers decide the purchase.
A freestanding bath is a self-supporting bath with a finished outer face on all four sides, connected to the waste and the taps rather than bedded into a surround. The catalogue range runs from vacuum-formed acrylic through mineral-filled solid surface to cast and natural stone, and each shell answers heat, load and repair differently.
The shell is the part you see and the part that decides almost everything else. A thin acrylic wall loses heat quickly and flexes under foot; a cast-stone wall holds heat and can weigh more empty than the water it holds. A quotation that names a length, a colour and a waste has left the floor, the overflow and the access to whoever arrives to fit it.
01Three shells, three different failures
The shell material decides how the bath fails, and that failure is what you will live with.
Acrylic is a thermoplastic sheet formed over a mould and reinforced underneath with glass-fibre and resin. Solid surface is a mineral-filled acrylic sheet, also thermoformed, but thick enough to be sanded and re-polished. Cast stone and natural stone are moulded or cut bodies with real mass; the surface is a gelcoat, a sealer or the stone itself.
| Shell | How the body is made | Typical failure | Repair route |
|---|---|---|---|
| Acrylic | Vacuum-formed sheet over glass-fibre and resin reinforcement | Flexing under foot; a crack at the overflow or waste hole | Surface fill and refinish; a cracked shell is replaced |
| Solid surface | Mineral-filled acrylic sheet, thermoformed and backed | Scratches, dull patches, a star crack at a fixing | Sanded and re-polished on site |
| Cast stone or composite | Moulded mineral body with a gelcoat finish | Chips at the rim; gelcoat wear at the overflow | Gelcoat repair; a rim chip stays visible |
| Natural stone | Cut and honed block, sealed | Etching, staining, chipping at an arris | Re-polish and re-seal; a chip is permanent |
A description of construction routes, not a ranking. Confirm the declared sheet or wall thickness in millimetres and the reinforcement schedule for the model quoted.
Decision rule: a timber upper floor and a fixed budget point to acrylic; a bathroom where the bath will be maintained and refinished points to solid surface; a concrete slab and a feature bath point to stone.
02Heat: the wall is the radiator
Treat heat retention as a specification line rather than a showroom impression: a bath cools at a rate set by the shell's thermal mass and insulation, and the open water surface loses heat whatever the shell does.
A thin acrylic wall has little mass and, unless it is insulated underneath, passes heat into the room quickly. A mineral or stone wall stores heat and gives some of it back, which is why a stone bath feels warm for longer at the start and cools more slowly at the end.
Make the comparison measurable rather than sensory. Fill both baths to the overflow at 40 °C in a room at 20 °C, leave them for 20 minutes, and read the water temperature 100 mm below the surface with the same thermometer. Record the drop; a drop above 2 °C in that window is a working threshold for comparing two shells, not a standard.
- Acrylic on a timber floor: ask whether a sprayed or blanket layer covers the underside and the base, and how it is fixed.
- Stone or cast body: the mass holds heat, so the gain is at the start of the bath rather than at the end.
- Overflow cut-out: check the insulation continues past it, because that is where the layer stops.
Decision rule: put the insulation, its coverage and the measured temperature drop on the RFQ, and compare two shells on the drop rather than on the brochure.
Catalogue reference: sanitaryware, baths and tapware — models, dimensions and finishes for the directions discussed above.
03Weight: 200 litres is 200 kg before anyone steps in
A filled bath is a concentrated load, and the average pressure over its footprint can exceed the load a domestic floor is designed for.
One litre of water is about 1 kg. A 1,700 × 750 mm bath covers 1.275 m² of floor; 200 litres plus an 80 kg bather is 280 kg, or about 220 kg/m². EN 1991-1-1 puts domestic floor loads in category A at 1.5–2.0 kN/m², which is roughly 150–200 kg/m². The arithmetic takes a minute and belongs before the order.
| Footprint (mm) | Area (m²) | Filled load (kg) | Average (kg/m²) |
|---|---|---|---|
| 1,400 × 700 | 0.98 | 280 | 286 |
| 1,500 × 700 | 1.05 | 280 | 267 |
| 1,600 × 700 | 1.12 | 280 | 250 |
| 1,700 × 750 | 1.28 | 280 | 219 |
| 1,700 × 800 | 1.36 | 280 | 206 |
| 1,800 × 800 | 1.44 | 280 | 194 |
Water volume is held constant to compare footprints. A larger bath holds more: substitute the supplier's fill volume to the overflow, in litres, and repeat the division.
The average is the smaller problem. A bath standing on four feet does not spread its load evenly: if 60% of 280 kg lands on two feet, each foot carries about 84 kg. Over a 50 mm pad that is 0.0025 m², and the local pressure is about 33,600 kg/m², or roughly 330 kN/m². That is why a spreading plinth, a bearer under the feet, or a check by the project's engineer is not an excess of caution on a timber floor.
04The floor: flat, stiff, and structural under the feet
The floor under a freestanding bath has to be flat, stiff and able to take a point load, and a tiled finish adds a brittle layer that will crack if the substrate moves.
Flatness is the first check. A 2 m straightedge should show no more than 3 mm of gap across the bath position, which is the same reference used for large-format tiling. The feet must bear on the structural layer or a properly fixed bearer, not on tile adhesive or a levelling compound alone.
- Measure the floor with a 2 m straightedge in both directions and record the gap in millimetres.
- Identify the joist direction and span, or confirm a concrete slab, and note it on the drawing.
- Divide the filled load by the footprint and compare it with the floor's design load from the engineer or the building's drawings.
- Specify the build-up under the bath: tile backer board on timber, or a levelling screed on slab, with the feet bearing through it.
- Leave an access gap for the waste and the trap, and check it before the floor is finished.
Decision rule: a timber floor with a span over 4 m, or any stone bath, needs a check by the project's engineer before the order is placed. A concrete slab at ground level may not, but the flatness and the access still do.
05Stone is a maintenance contract
Treat a stone bath as a maintenance contract: the surface is porous and acid-sensitive, and it needs sealing and careful cleaning for as long as it is installed.
Water absorption is the number that sets the risk. EN 13755 measures absorption at atmospheric pressure, and the declared value should be in the data sheet for the exact stone. A dense granite and a limestone sit far apart on that scale, which is why one bath stains on the first splash of oil and the other does not.
Acids are the second risk. Descalers, vinegar and some bathroom cleaners etch calcium-based stone, and the etch is a change of surface, not a stain that lifts. A chip at the rim is permanent; solid surface of the same shape can be sanded back.
- Weekly descaler in the household: choose solid surface or acrylic, or price re-polishing into the programme.
- Limestone or marble: ask for declared absorption to EN 13755, the named sealer and a re-sealing interval in months.
- Waste and tap holes: cut at the factory, because site drilling releases respirable crystalline silica and needs water suppression or extraction.
Decision rule: a stone bath without a declared absorption figure, a named sealer and a re-sealing interval in months is an unfinished specification.
06Drain and overflow: the 50 mm seal decides the smell
Buy the waste and the overflow with the bath, because together they decide whether it drains, smells or overflows.
Waste fittings are specified to EN 274, and the trap under the bath is covered by EN 12056-2, which calls for a water seal of at least 50 mm. A shallow bath shell sitting low over a timber floor is exactly where that 50 mm is hard to achieve, and where a slimline trap is fitted to make the numbers work.
Overflow capacity is the other half. At 0.3 litres per second a 200 litre bath fills in about 11 minutes, and the overflow has to pass that flow. A slot overflow in a thin rim passes less than a 40 mm overflow, so tap flow and overflow rating are read together.
- Void too shallow for a 50 mm seal: raise the bath or change the trap, and never shrink the seal.
- Slimline trap fitted: check the seal depth in millimetres against EN 12056-2 before signing.
- Overflow rated below the tap flow: change the overflow or the tap, because the slot will not pass what the spout delivers.
Decision rule: specify waste diameter, trap seal in millimetres and overflow capacity as three separate lines, and confirm the trap can be reached through an access panel without moving the bath.
07The RFQ page and the check on arrival
One page carries a freestanding bath: the shell, the four load numbers, the floor build-up and the waste.
- Declared empty weight and fill volume to the overflow, for the exact model.
- Shell thickness and reinforcement, or stone type and absorption to EN 13755.
- Foot count, foot pad size and whether a plinth is supplied.
- Waste to EN 274, trap seal not less than 50 mm, overflow capacity at least equal to the tap flow.
- Floor flatness at 3 mm over 2 m and the structural check reference.
- Access panel position and the clear space needed to remove the trap.
On arrival, check the crate against the approved model and finish before signing, stand the bath on its feet and put a straightedge along the rim, then fill and drain it once before the waste is connected permanently. A bath that rocks on a flat floor has a foot problem; one that rocks on an uneven floor has a floor problem, and different people resolve them.
What your RFQ should state
- Shell material and construction, with the declared sheet or wall thickness in millimetres.
- Declared empty weight in kilograms and fill volume to the overflow in litres, for the exact model.
- Number and size of feet, plus whether a load-spreading plinth is included.
- The filled load over the footprint in kg/m², and the floor's design imposed load to EN 1991-1-1.
- Waste to EN 274, trap seal of at least 50 mm to EN 12056-2, and the overflow capacity in litres per second.
- For stone, absorption to EN 13755, the named sealer and a re-sealing interval in months.
- An access panel for the trap, with its position on the drawing.
Where this guidance stops
- This article compares shell types and assemblies, not specific models. Two acrylic baths from different factories can differ in sheet thickness, reinforcement and flex.
- Floor loads, spans and deflection are structural decisions for the project's engineer. The arithmetic here is a check that the question gets asked, not a substitute for a calculation.
- The 2 °C heat-loss threshold and the 50 mm foot pad are working references for comparison, not standards, and the declared data for the model governs.
- A photograph or a sample chip cannot show absorption, wall thickness or how a shell is reinforced. That needs a data sheet, a physical sample and a written declaration.
- Foshan Supply coordinates sourcing, sampling and inspection. We do not test products, issue structural calculations or certificates, install baths, or offer a universal warranty; the supplier's declared data and the agreed inspection scope govern.
Questions buyers ask
Is a freestanding bath heavier than a built-in bath?
The water is the same weight; the shell and the support differ. A cast-stone or natural-stone freestanding bath can weigh well over 100 kg empty and carries its load through a few feet or a plinth, while a built-in acrylic bath spreads load through a timber cradle or a surround. Ask for the declared empty weight and the foot arrangement, then check the floor.
Will an acrylic bath feel flimsy?
It can, if the sheet is thin and the reinforcement is light. Flex under foot is a function of sheet thickness, the glass-fibre layer and how the base is supported, not of the material name. Ask for the declared sheet thickness in millimetres and stand in the bath on site before the floor is finished.
Do stone baths need sealing?
Yes, if the stone takes water. The sealer is what slows staining from oil, soap and dye, and a dense granite needs it less than a limestone. Ask for the absorption figure to EN 13755, the named sealer and a re-sealing interval in months. Acidic descalers etch calcium-based stone, so the cleaning instruction matters as much as the sealer.
Can a freestanding bath go on a timber floor?
It can, but it needs a check rather than an assumption. A 200 litre bath with a bather is about 280 kg, which over a 1.28 m² footprint is about 219 kg/m², above the top of the domestic range in EN 1991-1-1. Point loads at the feet are far higher. Ask the engineer to confirm the joists, the span and the bearer detail.
What size freestanding bath fits a 1,700 mm space?
A 1,700 mm bath is the nominal length that corresponds to a 1,700 mm opening, and EN 232 sets connecting dimensions so the rim and waste line up between manufacturers. The bath still needs clearance for the taps, the waste connection and the door swing. Measure the finished opening, not the studwork, and check the model's declared overall length.
Why does my freestanding bath drain slowly?
Check the trap before the waste. A shallow trap fitted to gain height under a low shell has a small water seal and a restricted path, and a flexible waste with a dip holds water and debris. The seal should be at least 50 mm to EN 12056-2, and the waste should be reachable through an access panel.
How many litres does a freestanding bath hold?
Use the declared fill volume to the overflow in litres for the exact model, not the outer dimensions. A 1,700 × 750 mm rectangle at 400 mm deep would hold about 510 litres as a box, but the internal shape, the base radius and the overflow height remove much of that. The declared figure is also the one to use in the floor-load arithmetic.
Sources
- EN 14516 — Baths for domestic purposes — British Standards Institution
- EN 232 — Baths: connecting dimensions — British Standards Institution
- EN 274 — Waste fittings for sanitary appliances — European Committee for Standardization (CEN-CENELEC)
- EN 12056-2 — Gravity drainage systems inside buildings: sanitary pipework, layout and calculation — British Standards Institution
- EN 1991-1-1 — Eurocode 1: actions on structures, general actions and imposed loads — European Committee for Standardization
- EN 13755 — Natural stone test methods: determination of water absorption at atmospheric pressure — British Standards Institution
- Construction dust: respirable crystalline silica and controls — Health and Safety Executive
Pages related to this guide
How this guide was checked
- Written from the public catalogue, the standards and regulator pages listed under Sources, and the process records described on the services page.
- Catalogue references and model details were checked on 2026-11-05; 7 primary sources are linked above.
- No supplier paid for placement. No price on this page is an offer; ranges are planning references and must be confirmed in a quotation.
How these guides are researched and reviewed · Corrections policy