In short
- Toughened glass is defined by EN 12150 and the assembled enclosure by EN 14428. A fragmentation report for the glass says nothing about whether the door will leak.
- The door leaks at the hinge side and the bottom sweep, not through the glass. The seal set, the tray upstand and the wall fixing decide the result.
- Toughened glass cannot be cut or drilled after tempering, so every hole, notch and edge must be on the drawing before the glass is fired.
A shower enclosure is the assembly that contains spray at a shower: the fixed glass, the doors, the hinges, pivots or runners that carry them, the wall profiles and the seals that close the gaps. It is certified as a unit to EN 14428 and glazed with safety glass to EN 12150 or, where the panel is also a barrier, laminated glass to EN ISO 12543.
That split matters because a quotation names a colour, a height and a thickness. It does not name the two standards, the seal set, the wall substrate the hinges are fixed into, or the tray the enclosure stands on. Those omissions are where a finished bathroom starts leaking into the room below.
01Toughened glass is tested, not promised
Toughening is a heat treatment, not a coating. The glass is heated and quenched, so the surfaces go into compression and the core into tension. Compression resists impact; tension decides how the panel breaks. EN 12150-1 covers the product and the fragmentation test.
The criterion is the number to know: at least 40 particles in a 50 × 50 mm square. A panel that breaks into large shards has not been toughened, whatever the label says, and the test runs on the thickness supplied.
| Glass type | Standard | What happens when it breaks | Where it earns its place |
|---|---|---|---|
| Annealed | No safety standard | Large sharp shards | Not in a shower |
| Toughened | EN 12150-1 | 40 particles or more in 50 × 50 mm | Fixed panels and doors |
| Heat-soaked toughened | EN 14179-1 | Same fragments; lower risk of spontaneous breakage | Frameless or full-height panels |
| Toughened-laminated | EN ISO 12543 | Fragments held in the interlayer | Low panels, barriers, half walls |
Fragmentation is tested on the supplied thickness; one result does not cover another thickness.
Decision rule: where the panel is a barrier as well as a screen — beside a bath, over a half wall — specify toughened-laminated. For a plain screen, toughened glass is enough; spend the difference on hinges and seals.
02Every hole is made before tempering
Glass is cut, drilled and edge-worked before it enters the furnace. After tempering, a cut, hole or notch shatters the panel: no site adjustment, no re-drill, no trimming a few millimetres off a panel measured against the studs rather than the tiles.
This is why the dimensioned schedule matters more than a photograph. One line per panel: width and height in mm, thickness, every hole measured from two datum edges, edgework, corner radius and door swing, all taken from the finished tile face.
Toughened glass can break without impact. Nickel sulphide inclusions can shatter a panel months after installation; heat soaking to EN 14179-1 reduces that risk without removing it, and it is a cost per square metre the buyer has to ask for.
- Check the permanent EN 12150 mark before installation; afterwards it is hard to prove which glass was fitted.
- Photograph each panel edge on arrival: a chipped edge is where a toughened panel later fails.
RFQ clause: all drilling, notching and edgework before toughening, against a dimensioned drawing approved by the buyer, with no site modification permitted.
Catalogue reference: shower enclosures, trays and sanitaryware — models, dimensions and finishes for the directions discussed above.
03The door is where the water leaves
Water does not pass through glass. It leaves at the gaps: the hinge side, the bottom edge where the door meets the tray, the joint between fixed panel and wall, and the corners where two profiles meet. A 2,000 mm door has a long seal line, and the sweep closing it is a consumable.
| Leak path | Cause | Detail that closes it | What to ask for |
|---|---|---|---|
| Hinge side | Spray thrown sideways past the edge | Hinge-side seal or deflector the door closes against | The seal as a named part, not 'included' |
| Bottom edge | Sweep not touching the tray, or pressed flat | Replaceable sweep set to the tray surface | Whether it changes without removing the door |
| Wall profile | Silicone applied to tile only | Continuous bead to the finished wall | Who applies it, and at which stage |
| Frame corners | Water standing inside the frame | Weep holes draining inward to the tray | Where the frame drains, and what blocks it |
The door should open outward, so water runs back to the tray and nobody is trapped behind it. The magnetic closure should pull it to the same line every time: a worn magnet shows as a gap at the handle side, where a leak starts.
Decision rule: price the seal set as line items — hinge seal, bottom sweep, magnetic strip, wall gasket — and buy one spare set per enclosure. A cheap enclosure with a poor sweep leaks; an expensive one with a worn sweep leaks identically.
04A frameless panel needs structure, not tiles
Fix a frameless panel to structure, not to tiles, because glass weighs 2.5 kg per square metre per millimetre: a 1,000 × 2,000 mm panel at 8 mm weighs 40 kg, with its centre of mass 500 mm from the fixing line. The fixings see an overturning moment, not just a weight.
Tiles, adhesive and plasterboard are a finish. The fixing has to reach the substrate the building was designed around — masonry, concrete, or framing fitted before the boards went up — and on a stud partition that is a pre-tiling decision, not a site remedy.
Hinges carry the door, which is heavier than it looks. Ask for the rated door mass and maximum door width per pair, and whether a third hinge is needed at full height. A door that has sagged shows as a gap at the sweep and a leak at the hinge side; neither is a glass fault.
- Stud partition, boards not yet up: framing or a ply pattress between the studs at the hinge and brace positions.
- Tiled wall with nothing behind it: a support bar to the opposite wall, or a floor-to-glass stabiliser, before the door goes on.
- Door wider than the hinge maker's rating: add the third hinge, or change the door type.
RFQ clause: state the substrate and fixing type at each point, the pull-out capacity assumed, and the hinge maker's rated door mass for the door size supplied.
05The tray, the upstand and the silicone line
The enclosure stands on the tray, and the tray meets the wall. EN 14527 covers trays; EN 14891 covers the liquid waterproofing beneath tiling. Neither installs the junction, and the junction is where a bathroom leaks into the room below.
An upstand lets the wall tiling lap over the tray edge, so water running down the wall cannot reach the joint behind it. A flat tray relies on the silicone line; there the waterproofing must run continuously to the tray and be dressed over the edge before tiling.
The frame-to-tray joint has a rule that runs against instinct: seal the outside and leave the inside open. Water behind the frame then drains into the tray instead of standing against the silicone. Sealing both sides traps it, and trapped water finds the floor below rather than the waste.
The trap must be reachable for cleaning, and a low-profile tray on a timber floor needs the recess formed before the tray is ordered. Ask for the trap depth and the access route.
06Profiles and finishes: what the adjustment hides
Very few walls are plumb. A wall profile has a cover channel with a limited allowance, and that allowance is the difference between a clean joint and a bead of silicone doing structural work. Ask for the range in millimetres per side, measure at three heights and put the readings on the drawing.
Inside the range, the profile absorbs the difference. Outside it, the answer is to pack the wall or make a return panel, not to fill the gap. A wide bead in a wet zone is a maintenance item with a short life.
Finish is a process, not a colour. Chrome plating, PVD, powder coating and lacquer behave differently in a wet room: PVD is harder and holds colour better, but the range is narrower. Ask what the process is, and for a profile sample, not a printed swatch.
Abrasive cream and acidic descaler remove plating and strip an easy-clean coating, which is a treatment with a service life, not a warranty. Pass the cleaning instruction to whoever cleans the room.
- Door type: a hinged, pivot, sliding or walk-in assembly each needs a different fixing detail.
- Glass thickness and heat soaking: both add cost per square metre, and heat soaking is invisible once installed.
- Seal set and spares: cheap with the order, expensive to source five years later.
07Measure after tiling, then order
A template taken before tiling is a template for the wrong wall: the finished face moves out by the adhesive bed and the tile, and the enclosure fixes to that face.
- Finish tanking and tiling, fix the tray and connect the waste.
- Measure the opening at three heights and the tray at three points; record millimetres, not 'standard'.
- Approve the dimensioned glass drawing, including hole positions and door swing.
- Confirm the seal set, the spare set, the hinge count and the finish against the approved sample.
- Agree crating: panels upright, edges protected, a counted number per crate, marked by room.
- Inspect on arrival: glass mark, edge chips, hinge count, seal parts, profile against the sample.
For identical bathrooms in a hotel or a block of flats, measure the first room after tiling, approve the drawing, then batch the rest. A few millimetres is absorbed by the profile, but a wall outside the adjustment range is a new panel and a new lead time.
Packing is part of the specification. Glass travels upright in a crate with edge protection, and a crate is never laid flat or stacked under tile cartons in a mixed container. Put the crate count and room marking in the order, and agree who pays for breakage at delivery.
What your RFQ should state
- Glass to EN 12150-1, with fragmentation evidence for the supplied thickness and the permanent mark on every panel.
- Heat-soaked glass to EN 14179-1 for frameless panels, and toughened-laminated glass to EN ISO 12543 where the panel is also a barrier.
- Enclosure assembly to EN 14428, with the report naming the size and door configuration supplied.
- A dimensioned glass drawing approved before production, with all holes and edgework completed before tempering.
- The substrate and fixing at each point, the pull-out capacity assumed, and each profile's adjustment range in millimetres.
- The tray to EN 14527 with upstand or flat edge stated, and waterproofing to EN 14891 continuous behind the tiling.
- The seal set as parts — hinge seal, bottom sweep, magnetic strip, wall gasket — with one spare set per enclosure.
- Who seals each junction, in writing, and the inspection point that photographs each one before handover.
Where this guidance stops
- This article describes standards and assemblies, not products: two enclosures certified to the same standard can differ in hinge quality, seal fit and finish life.
- A photograph cannot show the wall behind the tiles, the tray fixing, the fall, or how a seal will wear; those need a drawing, a site measurement and a named installer.
- EN 14428 defines the performance of the assembly; it does not design the junction. Local plumbing rules, the waterproofing approval and the building structure govern that detail.
- Nothing here makes a shower leak-free. Leakage depends on the tray, the fall, the tiling and the person who applies the silicone as much as on the enclosure.
- Foshan Supply coordinates sourcing, sampling and inspection. We do not test glass, issue certificates, install enclosures or warrant the result; the supplier's declared data and the agreed inspection scope govern.
Questions buyers ask
What glass thickness does a shower enclosure need?
Framed enclosures are commonly supplied in 6 mm toughened glass and frameless ones in 8–10 mm, as a planning reference rather than a rule. Thickness follows the panel size, the fixing and the door mass. Ask for the EN 12150-1 report for that thickness, plus the hinge maker's rated door mass for your door width.
Is toughened glass enough, or does it need to be laminated?
Toughened glass is enough for a screen that only contains spray. Where the panel is also a barrier — beside a bath, over a half wall, at a low level — specify toughened-laminated glass to EN ISO 12543: the interlayer holds the fragments in the frame instead of letting them fall.
Why does a shower door leak at the bottom?
The bottom sweep is the usual cause: it may not touch the tray, may be pressed flat so it cannot wipe, or the tray may fall away from the door. Check the sweep first, then the fall and the upstand.
Can a shower enclosure be cut or drilled on site?
No. Toughened glass cannot be cut, drilled or edge-ground after tempering, because the treatment puts the surface into compression and any interruption releases it. Every hole and notch must be on the drawing before the furnace. A site change means a new panel and a new lead time.
What does EN 14428 cover?
EN 14428 sets functional requirements and test methods for shower enclosures as assembled units, including water leakage and impact. The report has to name the size and configuration tested. A report for a 900 mm hinged door does not automatically cover a 1,200 mm sliding unit.
Does a shower tray need a tiling upstand?
It reduces risk rather than removing it. An upstand lets the wall tiling lap over the tray edge, so water running down the wall cannot reach the joint behind it. A flat tray relies on the silicone line and on continuous waterproofing behind the tiles. Either way, the EN 14891 membrane has to reach the tray.
How do I order enclosures for 40 identical bathrooms?
Finish and tile one room, measure it, approve the dimensioned drawing, then batch the order against that drawing. Check that the other rooms share the wall tolerance, because a wall outside the profile's range needs a new panel. Add one spare panel and one spare seal set per type.
Sources
- EN 14428 — Shower enclosures: functional requirements and test methods — British Standards Institution
- EN 12150-1 — Glass in building: thermally toughened soda lime silicate safety glass — European Committee for Standardization
- EN 14179-1 — Glass in building: heat-soaked thermally toughened soda lime silicate safety glass — European Committee for Standardization (CEN-CENELEC)
- EN ISO 12543 — Glass in building: laminated glass and laminated safety glass — International Organization for Standardization
- EN 14527 — Shower trays for domestic purposes — British Standards Institution
- EN 14891 — Liquid applied water impermeable products for use beneath ceramic tiling — European Committee for Standardization (CEN-CENELEC)
Pages related to this guide
How this guide was checked
- Written from the public catalogue, the standards and regulator pages listed under Sources, and the process records described on the services page.
- Catalogue references and model details were checked on 2026-11-05; 6 primary sources are linked above.
- No supplier paid for placement. No price on this page is an offer; ranges are planning references and must be confirmed in a quotation.
How these guides are researched and reviewed · Corrections policy