In short
- Window hardware is the locking and moving set: hinges or stays, handle and gearbox, espagnolette, locking points and keeps, plus rollers on a slider.
- A hinge or fixing that crosses the thermal break carries heat at about 160 W/(m·K) against 0.3 for the polyamide strip, and the Uw sum has no term for it.
- Specify the locking point schedule, the hinge grade to EN 1935 and the corrosion grade to EN 1670, then check the class report names your size.
Window hardware is the set of parts that moves and locks the sash: hinges or friction stays, the handle and gearbox, the espagnolette, locking points and keeps, and the rollers and track on a slider. The frame and glass decide the numbers on a label; the hardware decides whether the opening behaves like the tested product.
It matters when quotations are compared, because hardware is the easiest line to substitute and the hardest to see. Two windows from one profile, one with three locking points and a graded hinge, the other with two and an unrated one, declare the same Uw. Only one closes.
01The gasket seals only where a locking point pulls it
An air class is earned at the sash perimeter. EN 12207 grades air permeability from class 1 to class 4, and the grade belongs to a complete window on a rig, with the sash held shut by its own hardware. Depth and glass do not close that gap; the locking points do.
Each point pulls a cam into a keep and compresses the gasket over a short length of stile; between two points the gasket is held by its own memory. On a tall sash that span lifts first, because the stile bows under wind load, and the symptom is a mid-height draught.
Arithmetic makes the spacing visible. On a 1,200 mm stile, three evenly spaced points leave spans of about 300 mm; two leave 400 mm. That division does not settle the count, because the tested configuration does, but it tells you what to ask.
| Opening type | Hardware set | What fails first |
|---|---|---|
| Side-hung casement | Friction stays, espagnolette handle, cams at head and sill | Hinge drop; the top corner stops compressing |
| Tilt and turn | Corner drive, tilt restrictor, cams top and bottom | Slack corner drive; one mode leaks |
| Sliding | Tandem rollers, hook or mushroom lock, anti-lift block | Roller wear lets the sash sit off the gasket |
| Fixed light | No lock; setting blocks, gasket, drainage | Blocked weep holes; water stands in the rebate |
A window can combine types; a fixed light above an opening sash needs its own clause.
Decision rule: ask for the locking point schedule for the size you are buying, with positions on a drawing, and check that the air class report names the same size. A quote stating class 4 and nothing about configuration has quoted another window.
02A hinge is a load path before it is a finish
A hinge or friction stay carries the sash whenever it opens and holds it against wind when closed. The load is the sash mass, mostly glass.
Soda-lime glass runs at about 2,500 kg/m³, so each millimetre of glass adds 2.5 kg/m². A 1,000 × 2,200 mm sash is 2.2 m², and the glass alone weighs this much:
| Build-up | Glass thickness | Glass mass |
|---|---|---|
| Double, 4–16–4 | 8 mm | About 44 kg |
| Triple, 4–12–4–12–4 | 12 mm | About 66 kg |
| Triple, 6.4 mm laminated inner pane | 14.4 mm | About 79 kg |
Glass only. Frame, handle and any blind are additional; the rating must cover the total.
Hardware is rated by mass, not by sash height, which is where the arithmetic bites. A stay chosen for a 44 kg sash and fitted to a 66 kg one can hold on installation day and sag within a season. The sag widens the gap at the handle side and narrows it at the hinges; the gasket then compresses on one edge and lifts on the other.
EN 1935 sets requirements and test methods for single-axis hinges and grades them, so a grade is comparable rather than a claim. Ask for the grade, its cycle count and the sash mass it covers.
Decision rule: calculate the sash mass in kilograms, then require a declared rating above it, written into the quotation. A rating described only as heavy duty is not a rating.
Catalogue reference: windows and exterior doors in the catalogue — models, dimensions and finishes for the directions discussed above.
03A screw through the break spends the frame's number
Aluminium conducts heat at roughly 160 W/(m·K); the polyamide 66 strip with glass fibre that separates the inner and outer extrusion conducts at about 0.3. That ratio is why a broken profile works.
Indicative frame values run from 5.6–6.0 W/(m²·K) for plain aluminium to 3.0–3.5 on a 14.8 mm break, 2.0–2.8 on a 24 mm break and 1.6–2.2 on a 34 mm multi-chamber section. The EN ISO 10077-1 calculation adds glass area times Ug, frame area times Uf and glass perimeter times the edge transmittance. There is no term for a hinge.
So the calculation cannot defend you. A hinge leaf screwed through both extrusions, a bracket at the jamb or a keep that spans the strip hands heat a metal path around the insulation, and the local surface behaves like the plain aluminium figure while the window declares the broken one.
The remedy is a detail: an isolating washer under every screw head, a bush through the profile, a hinge plate on one extrusion only, fixings kept inside the warm zone. Ask for it as a 1:1 or 1:2 section drawing; no photograph shows it.
04The handle drives the points and the cylinder is the weak end
A handle is a lever: a spindle, a gearbox and a drive bar. A quarter turn should move every locking point through the same distance. Lost motion at the spindle, or slack in the gearbox, leaves the last point short of its keep, so a window can feel closed and leak at the far corner.
Test it on the sample. Close the window on a strip of paper at each point in turn, then pull. The paper should resist with a similar force at every point; if it slides out at one corner, that point is not engaging. A handle that rocks in its backplate loses compression the same way within a season.
Security rests on the same parts. The number and position of the locking points decide how many places a lever must overcome, and the keep decides whether the screw leaves the frame before the cam. A keyed handle is only as good as its cylinder.
Decision rule: put the count and position of locking points, the keep material and fixing, and the cylinder standard on the schedule. For a ground-floor or accessible opening, state whether a restrictor is required and whether it releases from inside for escape.
05Salt, cycles and drainage decide the second decade
Hardware fails slowly, then completely. The first sign is stiffness at the handle, then a white bloom at a hinge pin, then a roller that has flat-spotted and no longer pulls the sash onto the gasket.
Two declared grades cover most of it. EN 1670 sets corrosion resistance requirements and test methods for building hardware; EN 1935 covers hinge durability with a cycle count behind the grade. Neither predicts a site, but both are comparable. A pool room, a coastal facade and a city centre are three exposures, so the grade should follow the exposure.
Galvanic corrosion catches buyers. A stainless screw in an aluminium profile forms a small cell once water sits in the joint, and the aluminium loses. An isolating washer and a bead of sealant do more for the second decade than a thicker profile.
Drainage belongs in the same clause. A slider track needs a path for water past the brush seal, and a casement rebate needs a weep hole the sill detail does not bury. A blocked drain shows as water on the inner sill after driving rain, routinely read as a failed gasket.
Decision rule: state the EN 1670 corrosion grade and the EN 1935 hinge grade per elevation, and require the drainage path on the sill and track drawing.
06The label reports a product, not your opening
In the EU, EN 14351-1 is the harmonised product standard for windows and doors, and the CE mark accompanies a declaration of performance stating the classes claimed. In the US, the NFRC label reports U-factor, solar heat gain, visible transmittance and air leakage, and AAMA 1503 covers the frame test.
| Standard | What is tested | Where hardware enters |
|---|---|---|
| EN 12207, air, class 1–4 | Pressure applied to the closed assembly | Gasket compression, locking points, hinge stiffness |
| EN 12208, water, class 1–9A | Spray and pressure on the closed assembly | Gasket contact, drainage, corner joints |
| EN 12210, wind, class 1–5 | Pressure and deflection on the sash | Hinge and stay stiffness, spacing of locking points |
Each class is declared for a tested product and size; class 4 on a 1.2 m casement is not evidence for a 2.4 m sash.
Read the three as a set, and keep them apart from the energy figures. A window can reach class 4 on air, 9A on water and 5 on wind and still be wrong for a cold room, because none is an energy rating. Ug sits at 1.0–1.4 W/(m²·K) for a double unit and 0.5–0.8 for a triple, with argon worth roughly 0.1–0.2 in the same frame.
A CE mark or an NFRC label declares the product as placed on the market. It does not cover the fixing, the reveal or the sill, and it does not grade the hinge, which is why EN 1935 and EN 1670 are asked for separately.
Decision rule: require the class for the tested size, and the report page naming the configuration, the hardware set and the glazing build-up.
07Write the hardware schedule before you compare prices
One page per opening type turns a hardware argument into a comparison of like with like.
- List the openings by type, size and elevation.
- Name the hardware set for each type: hinge or stay, handle and gearbox, locking points and keeps, rollers and track.
- State the sash mass you calculated and the rating you require above it, in kilograms.
- State the air, water and wind classes for the tested size, with the report reference.
- State the corrosion grade to EN 1670 and the hinge grade to EN 1935 for each elevation.
- Attach the fixing and hinge isolation detail and require it on the approved drawing.
- Require the drainage path on the sill and track drawing, and the handover maintenance list.
Most of these cost a supplier nothing to answer, so a refusal is informative. A quotation returning a grade, a mass, a class and a drawing is comparable with another that does; one returning a brand name is an opening position.
The hardware set changes with the system. The System 120 range is a casement profile, so it carries friction stays and an espagnolette handle; the v76 casement window carries a comparable casement set in its own profile; a sliding profile carries tandem rollers and a hook lock instead; a wide fixed light in the windows and exterior doors range has no lock at all. Sourcing and inspection after the schedule are described under our services, and a schedule sent through the contact page can be compared line by line. The load a third pane adds to that hinge is worked through in the double versus triple glazing comparison.
What your RFQ should state
- The hardware set for each opening type, named part by part rather than by brand.
- The locking point count and positions, shown on a drawing for the size supplied.
- The calculated sash mass in kilograms and the declared rating above it.
- The hinge grade to EN 1935, with the cycle count behind the grade.
- The corrosion grade to EN 1670 for each elevation, with coastal and pool exposures named.
- The air, water and wind classes to EN 12207, EN 12208 and EN 12210 for the tested size.
- The fixing and hinge isolation detail, approved on a section drawing before production.
- The drainage path on the sill and track, and the handover maintenance list.
Where this guidance stops
- This article explains how hardware affects a window. It does not grade a product; two systems with the same profile can carry different hardware.
- A photograph cannot show hinge grade, gasket compression or cam engagement. Those need a sample and a hand test.
- The air, water and wind classes are measured on a rig at a stated size; the installed opening also depends on the fixing, the reveal and the sill.
- Corrosion grades are laboratory tests. Site exposure and the alloy actually supplied decide what happens at a coastal facade.
- Foshan Supply coordinates sourcing, specification review and inspection. We do not test, certify or install windows, and we do not issue performance declarations or a universal warranty.
Questions buyers ask
What counts as window hardware?
The moving and locking parts: hinges or friction stays, the handle and gearbox, the espagnolette, locking points and keeps, and on a slider the rollers and track. It excludes the frame and glass, which is why a hardware swap never shows in a U-value.
How many locking points does a window need?
It depends on the sash size and the configuration tested, so there is no universal count. On a 1,200 mm stile, three evenly spaced points leave spans of about 300 mm, two leave 400 mm. Ask for the schedule and the class report for that size.
Does hardware change the U-value?
Not in the calculation. The EN ISO 10077-1 sum counts glass, frame and the glass edge, and has no term for a hinge. A metal fixing across the thermal break lowers local frame performance, but the declared figure assumes an uninterrupted section, so the loss stays invisible.
Why does a window leak air at the handle side?
Usually because the last locking point is not reaching its keep. Slack in the gearbox, a rounded spindle, a dropped hinge or a frame fixed out of square will each leave the gasket uncompressed along one edge. The paper test at each point shows which it is within a minute.
Are hinges rated by weight?
By mass, yes, and by durability. EN 1935 grades single-axis hinges through test methods that include a cycle count. Compare the declared rating with the sash mass you calculate from glass and frame, not the size of the opening, and ask for the grade in writing.
What corrosion grade suits a coastal site?
A higher grade to EN 1670 than an inland site, plus a fixing detail that keeps water out of the joint. The grade is a laboratory result, so also ask which alloy the hinge, keep and screw use, and whether the fixings are isolated.
Does a CE mark cover the hardware?
Only indirectly. EN 14351-1 is the window product standard, and its declaration of performance states the air, water and wind classes for that product. Hinge and corrosion grades are separate declarations to EN 1935 and EN 1670, and the CE mark does not cover installation.
Sources
- ISO 10077-1:2017 — Thermal performance of windows, doors and shutters: calculation of thermal transmittance, Part 1: General — International Organization for Standardization
- EN 14351-1 — Windows and doors: product standard, performance characteristics — European Committee for Standardization
- NFRC ratings and the energy performance label: U-factor, SHGC, visible transmittance and air leakage — National Fenestration Rating Council
- AAMA 1503 — Voluntary test method for thermal transmittance of fenestration frames — American Architectural Manufacturers Association
- CE marking: the rules for placing products on the EU market — European Commission
- SS-EN 1935 — Building hardware: single-axis hinges, requirements and test methods — Swedish Institute for Standards, on behalf of CEN
- EVS-EN 1670:2007 — Building hardware: corrosion resistance, requirements and test methods — Estonian Centre for Standardisation
Pages related to this guide
How this guide was checked
- Written from the public catalogue, the standards and regulator pages listed under Sources, and the process records described on the services page.
- Catalogue references and model details were checked on 2026-11-05; 7 primary sources are linked above.
- No supplier paid for placement. No price on this page is an offer; ranges are planning references and must be confirmed in a quotation.
How these guides are researched and reviewed · Corrections policy