In short
- A pergola bolted down and carrying a covering is a structure. Furniture standards test a piece; EN 1991-1-4 wind actions and a base plate design test the installation.
- Velocity pressure follows a square law: 0.625 times the square of wind speed gives 391 Pa at 25 m/s and 563 Pa at 30 m/s, before exposure factors.
- Deflection, not strength, sets the span. Moving a beam from 3.0 m to 4.5 m multiplies bending by 2.25 and deflection by 5.06, so the section must change.
A pergola wind load is the force that wind pressure exerts on the frame, the covering and the connections of an outdoor canopy, calculated under EN 1991-1-4 and the local building code rather than read from a catalogue. The useful result is not a single wind speed but a load path: pressure on the canopy, bending in the beams, tension at the base plates, and the anchors holding those plates to a slab, a deck or a wall.
That path is why a pergola is a structure and not a piece of furniture. A lounger is tested as an object a person sits on. A pergola is tested by the building it is fixed to, and the same 4 × 3 m frame behaves differently on a 100 mm slab, on a timber deck and on paving over rubble. Most quotes name the finish and leave the anchorage to site.
01A fixed canopy is a structure, whatever the catalogue calls it
The label on the quotation decides which evidence you can demand, and many pergola quotes avoid it. A furniture test is cheaper than a structural calculation.
Outdoor furniture is tested as an object. EN 581 covers outdoor furniture for domestic, contract and public use; EN 1022 covers stability, EN 1728 strength and durability, EN 16139 contract seating. Those tests load a seat or a table the way a person does. None describes a 4 m beam carrying a fabric roof in a gale, because the load does not come from a person.
A fixed canopy is loaded by wind, by its covering and, on some sites, by snow. The reference is EN 1991-1-4 for wind actions, with the local code setting the design life and the safety factors. A calculation that is right in one country can be wrong in another because the basic wind speed differs, not the physics.
Decision rule: use furniture standards for anything that folds, moves or stands on its own weighted base; a structural calculation for anything bolted down that carries a roof. A supplier who cannot say which applies is not ready to be compared.
02Wind pressure rises with the square of velocity
Wind load begins with velocity pressure, a square law: double the speed and the pressure quadruples.
EN 1991-1-4 uses qb = ½ ρ vb². With air density at 1.25 kg/m³ that reduces to 0.625 vb², which is short enough to do before a meeting.
| Wind speed (m/s) | qb (Pa) | qb (kN/m²) | Change against 25 m/s |
|---|---|---|---|
| 20 | 250 | 0.25 | −36% |
| 25 | 391 | 0.39 | — |
| 30 | 563 | 0.56 | +44% |
| 35 | 766 | 0.77 | +96% |
Calculated from qb = 0.625 vb². A site value comes from the basic wind speed in the local code; these figures show the shape of the law, not a design value.
The basic value is then modified: terrain category, height, topography, then a pressure coefficient that turns pressure into a net force on the canopy.
That last step is the one buyers miss. A canopy is not a wall: wind pushes down on the top and pulls up on the underside, so the coefficient applies to the whole covered area with the sign reversed. Uplift, not downward load, usually decides the anchor.
The square law has a commercial consequence. A site at 30 m/s is not 20% harder than one at 25 m/s; it carries 44% more pressure, and the plate size or anchor count moves with it. Decision rule: give the supplier the site design wind speed in m/s and the exposure description in writing. A reply quoting Beaufort, or the phrase storm-rated, has calculated nothing.
Catalogue reference: pergolas and outdoor shade — models, dimensions and finishes for the directions discussed above.
03Span is limited by deflection before it is limited by strength
A beam span is limited by how far it sags, and sag grows with the fourth power of span while bending grows with the square.
On a uniform load and a constant section, doubling the span multiplies bending by four and deflection by sixteen. A pergola that looks right at 3 m does not stretch to 4.5 m unchanged.
| Span (m) | Bending vs 3.0 m | Deflection vs 3.0 m | What usually has to change |
|---|---|---|---|
| 3.0 | 1.00 | 1.00 | Reference section; check the connections |
| 3.5 | 1.36 | 1.85 | Same section may work; verify the limit |
| 4.0 | 1.78 | 3.16 | Deeper beam, or a mid-span post |
| 4.5 | 2.25 | 5.06 | Deeper beam, a steel insert, or an extra bay |
Relative values for a uniform load on a constant section. They show how fast the problem grows, not the capacity of any product.
Deflection is written as a fraction of span: L/200 for a member carrying light fabric, L/300 where the covering is rigid, a gutter has to drain, or the beam is seen against the sky. Your engineer sets the limit; it is written before the section is chosen.
Post spacing is separate: a 3 m bay with a 3 m beam gives 9 m² of canopy per frame; a 4 m bay gives 12 m² and loads the beam, not only the post.
Depth beats alloy, because stiffness rises with the cube of section depth. Decision rule: span, section depth and deflection limit go on one line of the drawing. A drawing with a span and no limit cannot be checked.
04The base plate is where the structure meets the building
Every load path ends at four or six base plates, and the substrate under them sets the capacity above.
Take a 3 × 4 m canopy, 12 m², at 0.56 kN/m² net uplift: 6.75 kN tries to lift it. Over four posts, each plate takes about 1.7 kN in tension before safety factors. Over six posts, about 1.1 kN each, with two more plates and eight more anchors to detail.
Tension is the hard part. A resin anchor good in shear can be weak in pull-out, which depends on concrete strength, embedment, edge distance and whether the hole was cleaned. A plate 100 mm from a slab edge is a different problem from one 400 mm in.
| Substrate | Common fixing | Question for the supplier | How it fails |
|---|---|---|---|
| Concrete slab | Cast-in or resin anchor | Embedment, edge distance, hole cleaning, waterproofing | Water under the plate; anchor corrodes |
| Timber deck | Through-bolt to the joist | Joist size, blocking under the board | Bolt lands in a board; board splits |
| Masonry wall | Bracket with anchors | Wall build-up, cavity, leaf thickness | Bracket pulls the outer leaf |
| Paving on mortar | None | Is there a pier down to the slab | Paving lifts with the plate |
| Blockwork | Chemical anchor | Block strength, hollow cores | Anchor spins in a hollow block |
No row recommends a product; the anchor data and the engineer's design govern.
Two details belong on the drawing: a pier where the slab is thin, unbonded or absent, and drainage, so the plate sits above the paving and water runs away from the anchor.
Decision rule: refuse a quote that leaves the anchor to site without a schedule. Fixed by others is a price, not a detail.
05The covering adds weight, and the motor adds a weak point
The covering decides whether the frame is a shade structure or a roof, and it changes the load, the fixing and the maintenance interval together.
Fabric quoted at 500 g/m² adds 0.5 kg/m². An 8 mm laminated glass roof adds about 20 kg/m², because glass weighs roughly 2.5 kg/m² per millimetre of thickness. On 12 m² that is 6 kg against 240 kg, a factor of forty before snow.
Weight is the visible load. The less visible one is wind: a louvred or glazed roof presents a different surface and may need the frame designed as a roof, with a fall, gutters and flashings.
Motorised louvres bring electrical equipment into the order. IEC 60529 codes IP65 as dust-tight and jet-resistant, IP67 as allowing temporary immersion. The cable gland, not the motor, is usually where water enters, so specify both to the same number.
Fabric is a wear item. Acrylic solution-dyed fabric holds colour better under UV than olefin, tested to ISO 105-B02 on a blue wool scale of 1 to 8. Ask for the rating and treat the fabric as a replacement part.
Decision rule: glass or a heavy louvre makes the frame a roof structure, so the calculation includes covering weight, snow and drainage. Fabric goes into the maintenance schedule with a replacement interval.
06Salt and standing water reach the fixing first
Aluminium does not rust, and the phrase hides the two failures that happen: a corroding fixing and a coating that has been cut.
Aluminium relies on an oxide layer, so bare extrusion in clean air lasts. In chloride — sea air, pool water, de-icing salt — the layer is attacked, and the attack concentrates at cut, drilled and scratched edges, which carry no powder coating. Water standing on a base plate keeps that edge wet.
The fixings are a different metal and a different risk. 304 stainless is common; 316 is specified for coastal salt. A stainless bolt in an aluminium post is a galvanic pair, and water between them makes a small battery. Ask whether the fixing is isolated, and what the detail is.
A six-post pergola has thirty-six fixing points — six plates, twenty-four anchors, six post-to-beam connections — before a louvre blade or a light. Replacing them is not touching up a scratch.
Decision rule: state the exposure — coastal, poolside, de-icing salt or inland — and require the grade, the isolation detail and the touch-up procedure to be named against it, with an inspection interval in the handover file.
07Put the calculation and the anchor schedule in the RFQ
One package makes one pergola comparable with another: the calculation, the base plate drawing, the anchor schedule and the covering data.
- Site design wind speed in m/s, exposure category and height, with the code reference and edition.
- The calculation, naming member sizes, spans, deflection limit and load combinations, signed by its author.
- A base plate drawing per condition — slab, wall, deck, pier — with plate size, hole centres and edge distances.
- An anchor schedule giving product, embedment, hole cleaning, torque and who installs it.
- Covering weight per square metre, fixing method, and the IP rating of any motor or light, gland included.
- Packing, and the touch-up specification for cut and drilled edges.
On arrival, check each plate against the drawing before assembly: hole centres, thickness, anchor count. A plate with the right footprint and the wrong centres is scrap, and cheaper to find on the ground than on a scaffold.
Decision rule: release the order only when the calculation, the base plate drawing, the anchor schedule and the covering data arrive as one package. A quote that prices the frame and leaves the anchorage to site has not priced a pergola.
What your RFQ should state
- The site design wind speed in m/s, the exposure category and the height, with the code reference and edition.
- The deflection limit for each beam as a fraction of span, and the span it applies to.
- A base plate drawing for each substrate condition, with plate size, hole centres and edge distances.
- The anchor product, embedment, hole cleaning, torque and who installs it.
- The fixing grade, 304 or 316, matched to the stated exposure, with the isolation detail.
- The covering weight per square metre, the snow case where it applies, and the drainage path.
- The IP rating for any motor, switch or light, including the cable gland.
- The touch-up specification for cut edges, and the inspection interval for base plates.
Where this guidance stops
- This article explains a load path, not a design. The calculation for your site needs an engineer working to the code that governs the project.
- The velocity pressures and span factors are arithmetic illustrations, not design values, and do not describe any product's capacity.
- A photograph cannot show whether a plate is 8 mm or 12 mm, how far the anchors sit from a slab edge, or whether the slab under the paving is structural.
- Coastal exposure, chlorine and de-icing salt are local conditions. The grade that suits one site may not suit another on the same coast.
- Foshan Supply coordinates sourcing, sampling, inspection and shipping. We do not design structures, issue calculations or certificates, install pergolas, or offer a universal warranty; the engineer's design and the supplier's declared data govern.
Questions buyers ask
How is pergola wind load calculated?
EN 1991-1-4 starts from basic velocity pressure, 0.5 × air density × wind speed squared. That value is modified for terrain, height and topography, multiplied by a net pressure coefficient and applied to the covered area. The result resolves into beam bending, connection forces and base plate uplift. The engineer needs the site wind speed, the exposure description and the geometry, not the colour.
What wind speed should I specify for a pergola?
Use the basic wind speed the local code sets for the site, and quote the code edition. Do not accept a generic catalogue figure. At the same air density, 25 m/s gives 391 Pa and 30 m/s gives 563 Pa: 44% more pressure on the same canopy, and a different anchor schedule.
Can a pergola be fixed to a timber deck?
Only if the fixings reach the joists or framing, with blocking where a post lands between them. A deck board is a walking surface, not structure, and a bolt through a board will split it or pull out under uplift. Ask for joist size, bolt detail and tension capacity.
Can I add a glass roof to a fabric pergola later?
Not without a new calculation. Fabric at 500 g/m² adds 0.5 kg/m²; 8 mm laminated glass adds about 20 kg/m², forty times as much on the same 12 m². Glass also changes the wind surface, the drainage and the snow case, so frame, plates and anchors are all checked again.
Does aluminium rust?
No, because there is no iron in it to rust. It does corrode: aluminium relies on an oxide layer, and chloride from sea air, pool water or de-icing salt attacks it. Cut edges, drilled holes and water trapped under a base plate are where it starts, and a stainless fixing in an aluminium post adds a galvanic pair.
How far apart can pergola posts be?
Spacing follows the beam span and the deflection limit, not a fixed number. On a constant section, 3.0 m to 4.5 m multiplies bending by 2.25 and deflection by 5.06, so a wider bay needs a deeper beam, a steel insert or a mid-span post.
What IP rating does a motorised pergola need?
IP65 is the usual starting point: dust-tight and resistant to water jets. IP67 adds temporary immersion and suits a louvre that can sit in standing water. The enclosure is only half the answer, because the cable gland is usually where water enters, so specify the gland to the same number.
Sources
- EN 1991-1-4 — Eurocode 1: Actions on structures, Part 1-4: General actions — Wind actions — European Commission Joint Research Centre
- EN 581 — Outdoor furniture: seating and tables for domestic, contract and public use — European Committee for Standardization
- EN 1022 — Furniture: seating — determination of stability — CEN-CENELEC
- EN 1728 — Furniture: seating — test methods for strength and durability — European Committee for Standardization
- EN 16139 — Furniture: strength, durability and safety — non-domestic seating — British Standards Institution
- IEC 60529 — Degrees of protection provided by enclosures (IP code) — International Electrotechnical Commission
- ISO 105-B02 — Textiles: tests for colour fastness to artificial light — International Organization for Standardization
Pages related to this guide
How this guide was checked
- Written from the public catalogue, the standards and regulator pages listed under Sources, and the process records described on the services page.
- Catalogue references and model details were checked on 2026-11-05; 7 primary sources are linked above.
- No supplier paid for placement. No price on this page is an offer; ranges are planning references and must be confirmed in a quotation.
How these guides are researched and reviewed · Corrections policy