In short

A solid core door is a leaf built around a timber or composite core that fills the space between its two faces, so the leaf acts as one thick slab; a hollow core door is a leaf built around a honeycomb or cardboard lattice, which is why the two sound different. Both can wear the same veneer and arrive on the same pallet.

The distinction changes three decisions that no sample board reveals: the load on the hinges and frame, the acoustic path through the leaf, and what a fire or acoustic certificate actually covers. A leaf price and a tested doorset price are different products.

01The core is a construction, not a grade

Solid covers several builds: timber staves, a particleboard block, or a denser composite. Hollow usually means a paper honeycomb or cardboard lattice with a light perimeter frame, skinned on both faces. The labels describe a principle, not a density, and density is where the behaviour lives.

The photograph above makes the point. That leaf is glazed, so its core is a glass panel and its mass comes from the glazing specification. The same question still applies: what is inside, in kilograms per square metre?

What each construction does differently, and the decision it drives
Property Solid core Hollow core Decision it drives
MassHigh for the leaf sizeA thin skin over airHinge count, frame fixing, handling
Screw holdingHardware fixes reliablyFixings pull out of the skinCloser and sign positions
ImpactDents; local damage repairableSkin punctures and delaminationWhere the door sits in a route
Acoustic routeMass limits leaf transmissionThe leaf is the weak pathWhether an acoustic set is needed
Fire routeCan form part of a tested setDepends on the tested designThe certificate, not the core name
Where it belongsEntrances, hotels, heavy useClosets, cupboards, low trafficRoom-by-room schedule

The table compares constructions, not brands. Two leaves labelled solid core can differ widely in mass, so the declared figure still has to be requested.

The decision rule: specify by declared mass and core, not by the word solid. A cupboard door and a hotel bathroom door do not need the same leaf, and one schedule that treats them alike overpays in one place and underperforms in the other.

02Weight is the number the hinge and the frame feel

Mass per square metre of finished leaf predicts everything downstream, and a quotation rarely states it. Ask for it in kilograms per square metre, for the leaf size you are buying.

Our arithmetic, not a supplier figure: a leaf 2,040 mm high and 826 mm wide is 1.69 m². At 25 kg/m² it weighs about 42 kg. A 44 mm leaf at 25 kg/m² has a mean density of 25 ÷ 0.044, or about 568 kg/m³ across skin and core. A timber or particleboard core clears that; a paper honeycomb behind two thin skins does not.

Forty-two kilograms is a two-person lift and a load the frame, not the plasterboard, has to take. Hinges must be sized for the leaf and fixed into something solid, the frame must be anchored into structure, and the closer must be chosen against leaf mass, because a light-leaf closer will fight a heavy leaf and slam it.

The decision rule: put the declared mass, the hinge count and type, the frame fixing and the closer size class on one line. A supplier quoting one hinge set for every door has not read the schedule.

Catalogue reference: interior doors and leaf constructions in the catalogue — models, dimensions and finishes for the directions discussed above.

03Cost sits in the face and the machining, not only the core

Two leaves in the same finish can differ in cost for reasons unrelated to the core: face, machining, certification, and whether a frame is included. Comparing a leaf price with a hung-set price is the commonest error in a door package.

Quote lines to compare per opening, with the unit each line should carry
Line What it covers Unit
LeafCore, face, edge, size, mass per m²Each, by leaf size
Frame or liningMaterial, rebate, finish, anchorageEach opening
MachiningHinges, lock, flush bolts, aperturesEach
SealsIntumescent, smoke, drop seal, thresholdMetre and each
IronmongeryHandles, locks, cylinders, closersEach, by schedule item
InstallationHanging, adjustment, making goodEach opening

A price per leaf and a price per opening are not comparable. Convert both to the same unit, with the same exclusions listed, before comparing totals.

The decision rule: ask for a priced schedule per opening, with exclusions written out, and compare totals only when the exclusion lists match. A supply-and-install figure that names no frame, seals or ironmongery is not comparable, and the missing item is usually the one that arrives late.

04Sound leaves through the perimeter before it leaves the core

A solid core leaf helps, and a gap defeats it. Performance is expressed as Rw in the laboratory or DnT,w on site under ISO 717-1, and the two are not interchangeable: Rw describes a specimen in a test frame, DnT,w a door in a wall with its seals, threshold and letter plate.

Approved Document E notes that lightweight doors with poor perimeter sealing insulate less than the wall they sit in. For a door onto a corridor in a flat it asks for good perimeter sealing, including the threshold, plus either 25 kg/m² of leaf mass or a tested set at 29 dB Rw, against 40 dB Rw for the internal wall and 45 dB DnT,w plus Ctr for a separating wall between purpose-built flats.

Read those as a hierarchy. The door is the weak element in a wall designed to a higher number, and a letter plate, a viewer, flush bolts or a gap under the leaf are each a hole that no leaf data sheet records.

Wall finishes do not rescue a leaking door. A 3D textile wallcovering is specified by roll width and pattern repeat on a flat, primed wall; it changes absorption in the corridor, not the perimeter gap.

05Fire is certified for the set, not the leaf

Fire performance is certified as a door set: leaf, frame, seals, hinges and hardware tested together under EN 1634-1 or the local equivalent. The leaf alone is not the rating, so every certificate has a boundary, and anything outside it is an untested assembly.

The seals are two components. Intumescent seals expand under heat and close the gap at the leaf edge. Smoke seals are separate and are required in many smoke-control applications, where the door must hold cold smoke long before anything ignites.

What a fire door certificate has to name, and why each line matters
Component Why it is in the rating What to ask for
LeafCore, thickness and size range testedThe size range and core supplied
FrameMaterial, rebate and fixing detailThe frame specified, not a substitute
SealsIntumescent and, where required, smokeThe seal product and position
HingesNumber, size and fixing patternA hinge schedule matching the leaf
HardwareCloser, lock, viewer, letter plateEach item named in the scope
GlazingGlass type and aperture sizeThe glazing specification tested

A certificate that names the leaf but not the hardware is a certificate for a different door from the one being installed.

The wall around the door belongs to the same problem. Fluted and slat panels are made in MDF, solid timber, aluminium or PET, and the fire class changes with the material, so a timber surround beside a fire door needs its own evidence. Read the certificate's field of application against the hardware, glazing and leaf size scheduled, and treat a certificate number without a scope as no evidence.

06Sizes belong to the opening, not the leaf

Sizes differ by market, and the difference is large enough to stop a container. US nominal widths are 30, 32 and 36 inches; UK leaves are 762 mm and 838 mm; European leaves are 800 mm and 900 mm. A schedule written in one convention and read in another produces leaves that fit nothing.

Leaf width conventions by market, and the dimension to schedule instead
Market Nominal leaf width What to schedule
United States30, 32 or 36 inStructural opening and floor level
United Kingdom762 mm or 838 mmOpening, frame rebate, floor finish
Europe800 mm or 900 mmClear opening and frame type
Any marketLeaf size is derivedOpening, frame, clearance, undercut

Widths are conventions, not a full size chart. Height, thickness and clearance vary by supplier and frame system, so the opening is the item to draw and approve.

Tolerance accumulates. The opening is built, the frame is fitted into it, and the leaf hangs inside the frame. Each step absorbs clearance, and the floor finish decides how much is trimmed from the bottom. A schedule that fixes the leaf and leaves the opening to the contractor pushes all of that onto the last trade on site.

The decision rule: schedule the structural opening, the finished floor level, the frame type and the clear opening, and let the leaf follow. State the undercut as a dimension, not an instruction to trim, and record it for fire and acoustic sets, where trimming can take a leaf outside its tested range.

07Entrance doors: a solid core is not a security rating

On an entrance door, solid core is a construction description used as if it were a security claim. Ratings vary by market, for example PAS 24 in the United Kingdom and RC classes under EN 1627, and they are awarded to a tested doorset, not to a leaf. The cylinder and the lock points matter as much as the leaf.

A leaf can be heavy, solid and easy to open with a lever in the wrong place. Resistance comes from the lock, the number and position of locking points, the cylinder and its protection, and the frame and its anchorage. Those are schedule items, and none of them needs a price to be named.

The decision rule: ask for the certificate for the doorset as supplied, with the cylinder and hardware fitted, and ask how many locking points engage and where. If the answer describes the leaf but not the lock, the certificate does not cover the product.

What your RFQ should state

  1. The core material and the declared mass per square metre of the finished leaf.
  2. The structural opening, finished floor level and clear opening for each door line.
  3. Whether each line is a leaf only, a hung set or a full doorset.
  4. The hinge count, frame anchorage and closer size class matched to the leaf mass.
  5. For a fire door, the certificate reference and its field of application, including hardware.
  6. The seal schedule, intumescent or smoke or both, with threshold and undercut dimensions.
  7. The acoustic target and route: a tested set to ISO 717-1 or a site measurement of DnT,w.
  8. For an entrance door, the PAS 24 or EN 1627 certificate for the doorset as supplied.

Where this guidance stops

Questions buyers ask

Is a solid core door worth the extra cost?

It depends on what the door has to do. Where the leaf carries a closer, takes trolley or luggage impact, or sits in a corridor, the heavier construction earns its place through screw holding, impact resistance and acoustic mass. For a closet or a low-traffic interior door, a hollow leaf is lighter and easier to hang.

How can I tell a solid core door from a hollow core door?

Ask for the declared mass per square metre and the core material. A hollow leaf is noticeably light for its size and usually sounds hollow when tapped, but a tap test is not evidence: a dense honeycomb core can sound similar to timber. A cut sample of the core or a declared mass is evidence.

Does a solid core door block more sound?

Mass helps, but the perimeter gap, the threshold and any letter plate dominate the result. A heavy leaf in a frame with poor sealing can perform worse than a lighter leaf in a well-sealed set. Specify the whole set now, then decide whether the target is a laboratory Rw or a site DnT,w.

Can a hollow core door be fire-rated?

A fire rating belongs to a tested set, not to a core type. The certificate names the core, frame, seals, hinges and hardware that were tested, and it defines which leaf sizes are covered. Ask for the field of application and check that the leaf, glazing and hardware you are buying fall inside it. A core name is not evidence either way.

What is the difference between Rw and DnT,w?

Rw is a laboratory rating of a specimen to ISO 717-1, usually in a test frame with controlled flanking. DnT,w is measured on site in a finished building, standardised for reverberation, and includes the wall, seals and installation. A set rated in the laboratory will not automatically deliver the same figure on site, so state which is required.

Do I need smoke seals as well as intumescent seals?

They are separate components with separate jobs. Intumescent seals expand under heat to close the gap at the leaf edge. Smoke seals resist cold smoke and are required in many smoke-control applications, where the door must hold smoke long before temperatures rise. Require both to be named in the certificate.

Should I schedule leaf sizes or opening sizes?

Schedule the opening. Leaf widths follow different conventions by market: US nominal widths of 30, 32 and 36 inches, UK leaves at 762 mm and 838 mm, European leaves at 800 mm and 900 mm. Once the opening, rebate, floor finish and undercut are fixed, the leaf size is derived.

Sources

  1. ISO 717-1:2020 — Acoustics: rating of sound insulation in buildings and of building elements, airborne sound insulation — International Organization for Standardization
  2. EN 1634-1 — Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware — European Committee for Standardization
  3. BS EN 1627 — Pedestrian doorsets, windows, curtain walling, grilles and shutters: burglar resistance, requirements and classification — BSI
  4. PAS 24 — Enhanced security performance requirements for doorsets and windows — BSI
  5. Approved Document E: resistance to the passage of sound — Ministry of Housing, Communities and Local Government
  6. Approved Document B: fire safety — Ministry of Housing, Communities and Local Government

Pages related to this guide

How this guide was checked

FS

Foshan Supply editorial team · Catalogue indexMethodology

Written in Foshan and reviewed against the catalogue and public standards on 2026-11-05. This page is a buying guide, not a quotation or a warranty. How we work.

How to cite this page: Foshan Supply, “Solid core door vs hollow core: weight, sound, cost”, 2026-11-05, https://foshansupply.com/blog/solid-core-vs-hollow-core-doors/