In short
- US nominal 30, 32 and 36 inch leaves convert to 762, 813 and 914 mm. UK leaves are 762 and 838 mm, EU leaves 800 and 900 mm.
- Schedule the structural opening, the frame and the clear width, not the leaf alone. The leaf is the last number in the chain.
- A fire rating belongs to a tested set under EN 1634-1, so a leaf trimmed on site is no longer the tested component.
An interior door size is the set of dimensions describing a leaf, its frame and the structural opening the frame sits in, three different measurements that a quotation often collapses into one. A 762 mm leaf is not a 762 mm opening.
The market decides which numbers you are offered. US schedules are drawn in nominal inches, British schedules in millimetres with two dominant leaf widths, European schedules in round metric widths. Where those families meet, someone converts, usually the party least able to check the result. It arrives in a container: leaves that fit their frames, frames that do not fit their openings, and a site team with a plane.
01Three width families that only look alike
The three markets use three sets of leaf widths, and only the 762 mm pair coincides, so a mixed schedule needs one declared system, not a conversion column.
| Market | Nominal leaf | Metric | Nearest neighbour | Where it goes wrong |
|---|---|---|---|---|
| US | 30 in | 762 mm | UK 762 mm | Width matches; lock and hinge prep do not |
| US | 32 in | 813 mm | None | No metric frame is built for it |
| US | 36 in | 914 mm | EU 900 mm | 14 mm wider; a clear width promised at 900 fails |
| UK | 762 mm | 30 in | US 30 in | The commonest false confidence in a mixed order |
| UK | 838 mm | 33.0 in | None | Custom run or a different schedule |
| EU | 800 mm | 31.5 in | None | Sits between US 30 and 32 in |
| EU | 900 mm | 35.4 in | US 36 in | Awkward beside imperial joinery |
Conversions are arithmetic, not a product range. Rebates, hinge types and lock cases differ even where the width agrees.
The 762 mm row is the trap. It is a genuine US 30 inch leaf and a genuine UK leaf, and buyers read the coincidence as proof that the markets interchange. They do not: lock case, hinge positions and frame profile are market-specific, so a UK 762 mm leaf in a US frame needs new machining, not a new dimension.
Decision rule: name the dimensional system and market at the top of the schedule, and require every quote in that system without conversion. A supplier converting an imperial drawing has made a design decision.
02The leaf, the frame and the opening are three dimensions
A schedule is only usable when it separates the structural opening, the frame and the leaf, because each is built by a different trade at a different time and each absorbs its own error.
| Dimension | What it describes | Controlled by | Failure if omitted |
|---|---|---|---|
| Structural opening | Hole in the wall: width, height, wall thickness | Main contractor | Frame cannot be fixed; a filler is invented on site |
| Frame | Outer size, rebate depth, profile | Joinery supplier | Fits the hole; leaf will not close into the rebate |
| Leaf | Width, height, thickness, edge detail | Door manufacturer | Trimmed on site, so certification no longer applies |
| Clear opening | Width and height free when open | Designer | Furniture or a wheelchair does not pass |
Wall thickness is a dimension too. A shallow frame leaves a reveal on one face and a proud architrave on the other.
Our calculation: a 762 mm leaf in a frame with 32 mm jambs and a 3 mm gap each side needs 762 + (2 × 32) + (2 × 3) = 832 mm of structural opening. An 838 mm leaf in the same frame needs 908 mm. The 76 mm difference is a blockwork module, so a late change of leaf width is a wall problem.
Height behaves the same way. Our calculation: a 2,040 mm leaf under a 40 mm head with 3 mm clearance needs a 2,083 mm opening before floor finish. A 15 mm rise in finished floor level spends that allowance.
Catalogue reference: interior doors and leaf sizes in the catalogue — models, dimensions and finishes for the directions discussed above.
03Clear opening decides what actually passes through
Clear opening is the width between the open leaf face and the opposite stop. It is always smaller than the leaf, so access and furniture checks must use it rather than the nominal size.
The US figure governing most accessible routes is 32 inches, or 813 mm, of clear width in the ADA Standards. That is close to a 32 inch leaf but not the same thing, and the gap is where projects fail inspection.
Our calculation, with a 45 mm leaf and a 30 mm stop: clear width ≈ leaf − 45 − 30. A 900 mm EU leaf yields about 825 mm and clears 813 mm. An 800 mm leaf yields about 725 mm and does not; a UK 838 mm leaf yields about 763 mm and fails too. That removes two of the three European stock widths.
Decision rule: derive the leaf from the required clear opening and the hinge type, never the reverse. A concealed hinge and a butt hinge project the leaf differently, so one leaf can give two clear widths.
04The wall build-up sets the reveal before the leaf is chosen
Frame depth comes from the wall, and the wall is rarely one material, so the opening must be scheduled with the finishes added after the frame is fixed.
A wall receiving a 3D textile wallcovering gains a layer on one or both faces, and that layer has a thickness. The wallcovering is specified by roll width and pattern repeat, and the wall must be flat and primed before installation, so the face the frame was set to is not the face the client sees. Fluted and slat panels behave the same way: MDF, solid timber, aluminium or PET, each with its own thickness and fire class.
At a fire door this matters most. A timber fluted surround beside a rated set introduces a combustible lining where the tested detail assumed a mineral one, and the fire class changes with the material. The set can be certified while the wall undoes the compartment.
Our arithmetic, with a 100 mm frame in a 140 mm wall: a 20 mm lining each face leaves it flush, and a 40 mm lining leaves a 20 mm reveal closed by an architrave or a shadow gap. Neither is wrong; discovering it after the frames arrive is.
RFQ clause: state finished wall thickness at each opening, the lining and finish build-up per face, and the frame depth required. Where a wallcovering or slat panel is scheduled, name the product and its declared thickness so the frame can be set to the finished face.
05A fire door is sized as a set, not as a leaf
Fire performance is certified for a door set, meaning leaf, frame, seals, hinges and hardware tested together under EN 1634-1 or the local equivalent, so the size that matters is the set size on the certificate.
This is where a size error becomes a compliance error. A leaf supplied 10 mm oversize and trimmed on site is no longer the tested leaf. Intumescent seals sit in a gap sized by the tested detail; widen it and the seal has more to close, narrow it and the leaf binds.
Smoke seals are separate from intumescent seals and many smoke-control applications need both. A set carrying the fire rating without the smoke seal has a different certificate scope, so the schedule must say which each opening needs.
Decision rule: schedule fire doors by set reference, not leaf size. Ask for the tested maximum trim per edge, the permitted gap at head and jambs, and the certificate covering the frame and hardware supplied.
06Sound leaves through the gap, not through the millimetres
Acoustic performance is expressed as Rw in the laboratory or DnT,w on site under ISO 717-1, and the two are not interchangeable: one describes a specimen, the other a room with a fitted door.
A gap or a letter plate can dominate the result. A 44 mm leaf with a good core, a 6 mm undercut, no perimeter seal and an unsealed letter plate will not deliver the laboratory number, and no leaf mass recovers it.
The forgotten dimension is the undercut. It is set by the floor finish and the clearance needed, and it is a hole. Carpet and tile need different undercuts, so state it per opening rather than leaving it to the site.
RFQ clause: require Rw for the leaf and DnT,w for the installed set, state the perimeter sealing and threshold detail, and confirm the undercut in millimetres.
07Write the schedule so the factory cannot guess
A schedule a factory can manufacture from carries the opening, the set, the leaf and the hardware on one line per door, with a reference that survives translation.
| Column | Example entry | Assumption it removes |
|---|---|---|
| Opening | D-07, level 3 corridor | Which hole in which wall |
| Structural opening | 908 × 2,083 mm, 140 mm wall | Frame size and fixing |
| Frame | Cased, 32 mm jamb, 40 mm head, 20 mm rebate | Whether a frame is included |
| Leaf | 838 × 2,040 × 44 mm solid core | Nominal width versus actual leaf |
| Set performance | FD30S, certificate reference quoted | Whether the rating covers frame and seals |
| Clear opening | ≈763 mm, stated by supplier | Access and furniture checks |
Example entries are illustrative, not a stock size. Every number must come from the project, and the supplier confirms the clear opening it produces.
Decision rule: approve one first article before the run. Measure leaf, frame and assembled set, hang it in a mock opening and check the clear width against the drawing. A 3 mm error on a leaf is a hinge adjustment; on a frame it is a wall.
Entrance doors run the same logic on different evidence: PAS 24 in the United Kingdom and RC classes under EN 1627 set the security frame, and the cylinder and number of locking points matter as much as the leaf.
What your RFQ should state
- The dimensional system and market the schedule was drawn in, with no conversion permitted without written approval.
- The structural opening width, height and finished wall thickness for every door, measured on site rather than scaled off a drawing.
- The frame type, jamb and head dimensions, rebate depth and profile drawing, stating whether the frame is in the price.
- The leaf width, height and thickness in millimetres, the core construction, and the permitted trim per edge.
- The clear opening the set will produce, checked against the accessible route and the largest item that must pass.
- For fire doors, the set performance and certificate reference covering leaf, frame, seals, hinges, closer and lock.
- For acoustic doors, Rw for the leaf and DnT,w for the installed set, with seal, threshold and undercut dimensions.
- The hardware preparation by opening, and the first-article record with measured dimensions before packing.
Where this guidance stops
- This article compares market conventions and the arithmetic linking leaf, frame and opening. It does not replace the project door schedule, which local regulation and the architect's drawings govern.
- The examples use round numbers for jambs, stops and gaps. Real frames vary by profile, so the supplier's drawing governs, not this arithmetic.
- A photograph shows the face of a door, not its core, its certification or its frame depth. Those need a data sheet, a certificate and a measured sample.
- Fire and acoustic performance depend on the installed set and the workmanship around it. No leaf specification survives a gap cut on site.
- Foshan Supply coordinates sourcing, sampling and inspection. We do not certify doorsets or issue fire test evidence; the supplier's declared data and the agreed inspection scope govern.
Questions buyers ask
What is a standard interior door size?
There is no single standard. US schedules use nominal 30, 32 and 36 inch leaves, which convert to 762, 813 and 914 mm. UK schedules use 762 and 838 mm; European schedules use 800 and 900 mm. Only 762 mm appears in more than one family, and lock and hinge preparation still differ, so the market of manufacture belongs in the specification.
Are UK and European door sizes the same?
No. UK leaves are 762 and 838 mm; European leaves are 800 and 900 mm. The difference looks like a tolerance and is large enough to stop a frame from fitting. An 838 mm leaf is 38 mm wider than an 800 mm leaf, and no rebate adjustment closes that. The two need separate door types, not a conversion note.
Can a door be trimmed to fit an opening?
Timber can be trimmed only within limits set by the manufacturer's certificate, and those limits are stated in millimetres per edge, not left to site practice. A hollow-core leaf has a perimeter frame that must survive. A fire door is certified as a set, so trimming beyond the tested allowance takes it out of scope. Ask for the permitted trim per edge in millimetres.
What is the difference between leaf size and clear opening?
The leaf is the panel that swings. The clear opening is the space left when it is open, reduced by leaf thickness, the stop and hinge geometry. A 900 mm leaf at 45 mm thick with a 30 mm stop gives roughly 825 mm clear. Access and furniture checks must use that figure, not the leaf width on the schedule.
Do interior doors need to be fire rated?
It depends on the building and the door position. Doors onto a corridor, a stair enclosure or a plant room are commonly rated, and the requirement comes from local regulation and the fire strategy. Where a rating applies, specify a tested set under EN 1634-1 with seals and hardware included.
How many millimetres is a 32 inch door?
A 32 inch leaf is 812.8 mm, rounded to 813 mm. It has no metric equivalent, so an 800 mm frame will not accept it, and an 813 mm opening will not accept an 800 mm frame with normal clearance. Where a drawing mixes inches and millimetres, resolve leaf and frame together.
How should door sizes be specified for an apartment schedule?
One line per opening, with structural opening, frame, leaf, clear opening, set performance and hardware preparation. Add finished wall thickness and the undercut. Approve a first article and measure it before the run. For a repeated layout, keep one door type per opening size so a replacement leaf can be ordered without a site survey.
Sources
- EN 1634-1 — Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware — European Committee for Standardization
- ISO 717-1:2020 — Acoustics: rating of sound insulation in buildings and of building elements — International Organization for Standardization
- EN 1627 — Pedestrian doorsets, windows, curtain walling, grilles and shutters: burglar resistance — European Committee for Standardization
- PAS 24 — Enhanced security performance requirements for doorsets and windows — British Standards Institution
- 2010 ADA Standards for Accessible Design — doors, clear width and manoeuvring clearance — US Access Board
- Approved Document M — Access to and use of buildings — UK Ministry of Housing, Communities and Local Government
Pages related to this guide
How this guide was checked
- Written from the public catalogue, the standards and regulator pages listed under Sources, and the process records described on the services page.
- Catalogue references and model details were checked on 2026-11-05; 6 primary sources are linked above.
- No supplier paid for placement. No price on this page is an offer; ranges are planning references and must be confirmed in a quotation.
How these guides are researched and reviewed · Corrections policy