In short
- Rw is a laboratory rating for a tested specimen, so an acoustic window is only as good as the make-up and the size named in its report.
- Mass and damping live in the glass. The frame, the gaskets and the perimeter seal decide how much reaches the room.
- Ask for Rw with Ctr, the air class to EN 12207 and the specimen size. A CE mark alone says nothing about installed sound.
An acoustic window is a window assembly specified and rated for airborne sound insulation, expressed as a single number Rw and bought on the strength of a test report that names its glass make-up, its frame and its size. The glass carries the mass. The frame and the perimeter seals decide how much of that mass reaches the room as quiet.
A line reading Rw 40 dB looks like a specification and behaves like a wish until the make-up and size are attached. A substituted interlayer, a different spacer or a sash 200 mm narrower produces a different number, and the opening that gets installed is the one that counts. This guide follows a 40 dB target through the four places it is lost: the rating, the mass, the frame and the leak.
01Rw is a laboratory rating, not a property of the room
Rw is a single-number rating calculated from a laboratory test, so it describes a specimen in a test opening, not the window in your wall.
Under ISO 10140-2 the specimen is fixed between two rooms and measured in one-third-octave bands; EN ISO 717-1 compares that curve with a reference and shifts it until the differences fit. The shift is the rating, and the reference is a shape, not your street.
The adaptation terms matter as much as the headline. C weights speech and television; Ctr weights traffic and aircraft. A window with a sound Rw and a weak Ctr quiets a party and lets lorries through.
The field value, R'w, is the one that counts. Reveal, sill, wall junction and structural transmission sit outside the specimen, and no deduction converts one into the other. STC, from ASTM E413, has no published conversion to Rw.
| Label | Method | What it rates | What it leaves out |
|---|---|---|---|
| Rw | EN ISO 717-1 on ISO 10140-2 data | Insulation of a laboratory specimen | Reveal, site seal, installed size |
| Rw + Ctr | EN ISO 717-1 adaptation term | The same specimen, weighted for low frequency | Everything outside the test frame |
| STC / OITC | ASTM E413 or E1332 on ASTM E90 data | The same idea on a US scale | Any equivalence to Rw; none is published |
A label proves a test was run on something; confirm it was your window.
Decision rule: accept a data sheet only when it names the rating, the method, the specimen size and the glass make-up.
02Mass sits in the glass, so the make-up is the specification
Insulation rises with the surface mass of the separating element, which is why an acoustic window is a heavy one and why the weight belongs in the quotation.
Calculation, not a catalogue figure: glass at about 2,500 kg/m³ weighs 2.5 kg per square metre per millimetre, so a 6 mm pane is about 15 kg/m² and a 10 mm pane about 25 kg/m². On the 1.34 m² area below, the 10 mm pane alone is roughly 33 kg before the sash is added.
That mass is felt before it is heard. Hinges, friction stays and restrictors are rated for a leaf weight, and a stay chosen for a 6 mm unit sags under a laminated one. A thicker unit needs a deeper rebate, and freight is loaded by weight before volume.
Mass alone is blunt: equal panes resonate in the same band, so asymmetric build-ups separate those bands and a 6/16/8 unit often beats a heavier symmetrical one. Decision rule: specify the make-up pane by pane and check the hardware against the leaf weight.
Catalogue reference: aluminium window and exterior door systems — models, dimensions and finishes for the directions discussed above.
03Damping is the interlayer's job, and thickness is not damping
Glass has a coincidence dip: at a frequency set by its thickness, the bending wave travels at the speed of sound in air, the pane radiates efficiently and insulation falls in that band. Thickness moves the dip; it does not remove it.
Lamination damps it. A viscoelastic interlayer turns some bending energy into heat and lifts the dip rather than shifting the curve, and an acoustic grade does that better than a standard safety interlayer of the same thickness. Laminated is not yet a specification.
Cavity and gas are separate duties. A wider cavity helps the low frequencies; argon mainly improves the thermal figure, lowering Ug by roughly 0.1–0.2 W/(m²·K) in a typical double unit. A supplier optimising thermal figures can supply a mediocre acoustic build-up.
Decision rule: name the interlayer product and its nominal thickness, state both pane thicknesses, and require the report to state them too.
04The frame is a fifth of the area and most of the weak path
The frame is a minority of the opening but carries every joint, so calculate its area share first.
A 1,200 × 1,400 mm opening with a 70 mm visible frame has 1.68 m², of which the glass is 1.06 × 1.26 = 1.34 m², or 79%. The perimeter to be sealed is 2 × (1.06 + 1.26) = 4.64 m. At 900 × 1,000 mm the glass share falls while the perimeter stays long, which is why a small bathroom window is worse than the slider beside it.
The thermal data reads the section, not the sound. Aluminium conducts heat at roughly 160 W/(m·K); polyamide 66 with glass fibre, the strip between the extrusions, at about 0.3 W/(m·K). A 34 mm multi-chamber profile is several chambers deep. None of it predicts Rw: a break is a bridge of low conductivity, not a vibration isolator.
| Frame construction | Indicative Uf | What the section shows | What it cannot show |
|---|---|---|---|
| Plain aluminium, no break | 5.6–6.0 | One metal path; the gasket is the only separation | Sound: a heavy section can be a poor insulator |
| 14.8 mm polyamide break | 3.0–3.5 | One strip, one chamber, shallow profile | Rw: the break is a rigid tie, not a damper |
| 24 mm break | 2.0–2.8 | Two chambers, deeper profile, room for a second gasket | The number of seal lines actually fitted |
| 34 mm multi-chamber | 1.6–2.2 | Deep section, wider rebate for a heavier unit | Any acoustic figure without a test |
Indicative ranges for reading a quotation, not certified values for a named profile.
Decision rule: calculate the glass share for the smallest and largest opening, and ask for Rw at both sizes.
05An unsealed slot sets the installed number
Sound takes the easy path, and an aperture is easier than mass. A window rated at 40 dB in a laboratory can behave worse in a room because a drainage slot, a vent or a dry gasket lets the pressure through.
The leak is rarely a hole in the glass. It is the pressure-equalisation slot that keeps drainage working, the trickle vent required for ventilation, the meeting stile of a slider, the corner where two gaskets meet without compression, and the joint behind a sill sealed on one face.
EN 12207 classifies air permeability in classes 1 to 4, class 4 the tightest. It is the closest thing a schedule has to an acoustic proxy, because it describes leakage under pressure. It is not a sound rating and cannot be converted into one, but a class 1 or 2 window leaks by design and no glass recovers what escapes past it. EN 12208 covers watertightness 1 to 9A and EN 12210 wind 1 to 5; wind drives deflection and leakage together.
Decision rule: fixed glazing outperforms an opening sash of the same make-up. Keep glass facing the source and test one installed opening.
06Fixings and hardware hand vibration a shortcut
A metal fixing or hinge that crosses the thermal break short-circuits it locally, and the same rigid tie gives vibration a path from outer frame to inner.
The list is longer than buyers expect: hinge leaves and screws, friction stays, restrictors, lock cases, corner cleats and the installation brackets. Each is metal in contact with both sides of a separation the design works to maintain. The thermal result is condensation on a cold morning; the acoustic one is a hum the gasket would have absorbed.
Hardware also decides how the sash closes. A multi-point lock pulls the sash onto its gasket around the full perimeter; a single handle with two keeps leaves the middle of a long edge loose, and on a 1.4 m sash that gap is audible.
Decision rule: require a non-metallic separator at every crossing, the fixing detail by drawing, and isolation between bracket and inner face, then check the drawing at inspection.
07Labels prove a product, the report proves a make-up
A CE mark declares conformity for the characteristics the manufacturer chooses to declare, and acoustic performance is not always among them.
EN 14351-1 is the harmonised product standard behind the declaration of performance. Read the declaration, not the mark: it lists the characteristics declared, the classes achieved and the standards used, and the acoustic line may be absent. A CE mark does not certify the installed opening or the wall junction, and a test on one size does not certify another.
The US label answers different questions. NFRC 100 and 200 report U-factor, SHGC, visible transmittance and air leakage; AAMA 1503 is a thermal test. Neither reports Rw.
The acoustic evidence is a separate report. Ask for it in this order.
- The rating and method: Rw and Rw + Ctr to EN ISO 717-1, measured to ISO 10140-2.
- The specimen: size, frame profile, sash configuration, and make-up with pane thicknesses, cavity, gas and interlayer.
- The laboratory, date and report number.
- The air class to EN 12207, water and wind classes to EN 12208 and EN 12210.
- The fixing and hardware detail assumed in the test, including isolation at the break.
- Any vent, with its own rating and closed-position leakage.
Decision rule: no acoustic figure reaches the schedule without the report behind it, attached to the order and enforced at inspection.
What your RFQ should state
- The rating per opening type, as Rw and Rw + Ctr to EN ISO 717-1, measured to ISO 10140-2.
- The specimen size and glass make-up the rating applies to, pane by pane, with cavity, gas and interlayer.
- The glass weight per square metre, so hardware can be checked against leaf weight.
- Air permeability class 4 to EN 12207, with water and wind classes to EN 12208 and EN 12210.
- The number of gasket lines, the drainage detail, and whether any pressure-equalisation slot opens to the room.
- The ventilation strategy, with a rated acoustic performance and a sealing closed position for any vent.
- Non-metallic isolation at every fixing, hinge, stay and bracket crossing the break, by drawing.
- The report number, laboratory and date, attached as an appendix, with substitution under written approval.
Where this guidance stops
- This article explains how rating, glass, frame and leakage interact. It does not predict the sound level in a room, which depends on source spectrum, absorption, the reveal and flanking.
- The Uf values are indicative ranges from supplier data, not certified figures for a named profile. They are used to read a section, not as declared performance.
- The 40 dB figure is a schedule target used to organise the argument. Whether an assembly reaches it is a question for a test report on that assembly.
- Acoustic requirements for dwellings come from national building regulation and planning conditions, which differ by jurisdiction and may ask for a different quantity from the supplier's sheet.
- Foshan Supply coordinates sourcing, sampling and inspection. We do not test, issue acoustic reports or certificates, or warrant installed sound performance.
Questions buyers ask
What does Rw 40 dB mean on a window specification?
It is a single-number rating to EN ISO 717-1, calculated from a laboratory measurement to ISO 10140-2. It describes a tested specimen, not your wall. A 40 dB window installed with a leaky reveal, a trickle vent or a dry gasket will not deliver 40 dB in the room.
Is Rw the same as STC?
No. Rw comes from EN ISO 717-1 and STC from ASTM E413, each with its own reference contour and band range, and no standards body publishes a conversion. A US sheet may quote STC and a European one Rw for the same product. Compare only like with like.
Is laminated glass always better for sound?
Usually, because the interlayer damps the coincidence dip, but only if the interlayer suits the job. A standard safety interlayer of the same thickness does less than an acoustic grade, and a poorly matched symmetrical unit can be beaten by an asymmetric one. Ask for the interlayer product and thickness.
How much does a thermal break help with noise?
Very little, and buying an acoustic window on its Uf is a mistake. A break is a structural bridge of low conductivity: it separates heat paths while still tying the extrusions together. Sound through a frame depends on its mass, its gasket lines and how well the sash compresses onto them.
Why does my quiet window still let traffic noise through?
The usual causes are a leak path and a low-frequency mismatch. Drainage slots, trickle vents, a corner gasket without compression or a joint sealed on one face will pass sound whatever the glass. Traffic energy sits low, where Rw alone flatters a window, which is why Ctr exists.
Should I specify fixed glazing to meet a noise target?
Where the schedule allows it, yes. A fixed pane removes the sash joint, the lock line and the compression question, so it is the easiest part to make airtight. The trade-off is ventilation: a habitable room needs air, and a vent becomes the new weak point.
What documents should I ask for before approving an acoustic window?
The test report to ISO 10140-2 with the rating to EN ISO 717-1, naming size, frame, sash and make-up; the declaration of performance under EN 14351-1; air, water and wind classes to EN 12207, EN 12208 and EN 12210; the fixing drawing with isolation details; and any vent's own performance.
Sources
- ISO 10077-1 — Thermal performance of windows, doors and shutters: calculation of thermal transmittance — International Organization for Standardization
- EN 14351-1 — Windows and doors: product standard, performance characteristics — European Committee for Standardization
- NFRC 100 and 200, and the NFRC certified product label — National Fenestration Rating Council
- AAMA 1503 — Voluntary test method for thermal transmittance of windows, doors and glazed wall sections — American Architectural Manufacturers Association
- CE marking under the Construction Products Regulation — European Commission
- ISO 10140-2:2021 — Laboratory measurement of sound insulation of building elements: airborne sound insulation — International Organization for Standardization
- EN ISO 717-1:2020 — Rating of sound insulation in buildings and of building elements: airborne sound insulation — National Standards Authority of Ireland
Pages related to this guide
How this guide was checked
- Written from the public catalogue, the standards and regulator pages listed under Sources, and the process records described on the services page.
- Catalogue references and model details were checked on 2026-11-05; 7 primary sources are linked above.
- No supplier paid for placement. No price on this page is an offer; ranges are planning references and must be confirmed in a quotation.
How these guides are researched and reviewed · Corrections policy
